General Informations
5500 EMV Single Phase Block Filter: AC Filter for PCB Mounting
Standard- or Medical-Filter
|
Shield
|
|
Description
| - |
Component: PCB Mounting |
| - |
1 Function: Line filter in standard and medical version |
| - |
For PCB mounting |
Approvals
| - |
VDE Certificate Number:101307 |
| - |
UL File Number:E72928 |
Characteristics
| - |
Ultra-compact design |
| - |
Shield available separately (German silver) |
| - |
Qualified for use in equipment according IEC/EN 60950 |
Weblinks
pdf,
General Product Information , Approvals,
RoHS ,
CHINA-RoHS ,
Mating Connectors , e-Shop, SCHURTER-Stock-Check, Distributor-Stock-Check,
Accessories ,
Product News
| Ratings IEC |
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz |
| Ratings UL/CSA |
1 - 10 A @ Ta 40 °C / 125 VAC; 60 Hz |
| Leakage Current |
standard < 0.5 mA (250 V / 60 Hz) medical < 5 µA (250 V / 60 Hz) |
| Dielectric Strength |
> 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) |
| Allowable Operation Temp. |
-25 °C to 85 °C |
| Climatic Category |
25/085/21 acc. to IEC 60068-1 |
Degree of Protection
[?]
Term: IP-Protection
Explanation:
The IP code consists of a two-digit number, which indicates the respective degree of protection.
The first digit specifies the protection from the penetration of foreign objects, the second digit the protection from water penetration with harmful effects.
I. index number: protection from the penetration of foreign objects 0 non-protected
1 ≥ 50 mm diameter (back of hand)
2 ≥ 12.5 mm diameter (finger)
3 ≥ 2.5 mm diameter (tool)
4 ≥ 1 mm diameter (wire)
5 dust-protected
6 dust-tight
II. index number: protection from water penetration with harmful effects
0 non-protected
1 vertically dripping
2 dripping (15° tilted)
3 spraying
4 splashing
5 jetting
6 powerful jetting
7 temporary immersion (1 m, 30 min)
8 continous immersion 9K: water at high pressure / steam jet cleaning (Water that is addressed against the housing from any direction under increased pressure, should have no harmful effects.
|
from front side IP 40 acc. to IEC 60529 |
| Protection Class |
Suitable for appliances with protection class 1 acc. to IEC 61140 |
| Terminal |
For PCB mounting |
| Material: Housing |
Thermoplastic, UL 94V-0 |
| Line Filter |
Standard and Medical Version, IEC 60939, IEC 60601 1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8
Technical details
|
| MTBF |
> 5'900'000 h acc. to MIL-HB-217 F |
| Line Filter |
|
| Shield |
|
|