Components / Connectors / Power Entry Modules without Filter

Power Entry Modules without Filter

Indicated types: 1 - 20 of 50

  • T/S:

Picture(s)Approvals [?]
Term: Approvals
Explanation: Approvals indicate the conformity of the products with the national testing institution requirements by listing of the relevant approval logos.

appr = Approvals

The link leads you to the certificates of the selected products.

Detailed Information about the listed Approvals

Approbations-Logos see: Approval Information can be looked up in the general product informations.

For further assistance: schurter.webleads@schurter.ch
Type [?]
Term: Type
Explanation: The Type describes the Product line or the so-called series. It includes the different product variants, which are provided with a unique article.

html = Data Sheet in HTML format

pdf = Data Sheet in PDF format

CAD = 3D CAD-Drawings

appr = Approvals

e-store = e-Shop

PCS = Product Content Sheet (PCS)

PCN =

Product Change Notification (PCN)



1) = RoHS

2) = China RoHS

conform

3) = not China RoHS

conform

For further assistance: schurter.webleads@schurter.ch
Matching ComponentsRated Current [?]
Term: Rated Current
Explanation: Max. rated current according to IEC vs. UL/CSA- approval for the listed type. Further details see data sheet

For further assistance: schurter.webleads@schurter.ch
MountingTerminalsLine Switch [?]
Term: Line Switch
Explanation: Also includes circuit breaker switch and parts with switches for bowden cable actuation.

For further assistance: schurter.webleads@schurter.ch
Circuit Breaker [?]
Term: Circuit Breaker
Explanation: Circuit breaker for equipment and amount of switched poles

For further assistance: schurter.webleads@schurter.ch
Fuseholders [?]
Term: Fuseholders
Explanation: Integrated fuseholder

For further assistance: schurter.webleads@schurter.ch
Voltage SelectorsIEC Type [?]
Term: IEC Type
Explanation: Connector type according to IEC 60320-1 resp. IEC 60320-2-2, UL498, CSA C22.2 no.42

For further assistance: schurter.webleads@schurter.ch
Version with Line Filter [?]
Term: Version with Line Filter
Explanation: Same functional version additional with line filter

For further assistance: schurter.webleads@schurter.ch
ApplicationComment
IEC UL
MethodSnapper [?]
Term: Snapper
Explanation: Snap mounting might be separated in more detailes as follows:

One Step: Indicates types for sandwich mounting for one fixed panel thickness

Individual step: Indicates snappers for different panel thickness dimensions. e.g. 1.0mm, 1.5mm

Universal: Indicates serrated snappers fitting a range of panel thickness dimensions, e.g. 0.8mm - 1.2mm

For further assistance: schurter.webleads@schurter.ch
Position [?]
Term: Position
Explanation: Mounting position: Indicates orientation of screw holes of snappers in relation to the connector position

Mounting position 1

o

-- --

--

o

Mounting position 2

-- --

o o

--

For further assistance: schurter.webleads@schurter.ch
SideTypeNumber of Poles
  • NEW
  • 2) CHINA-RoHS conform [?]
    Term: 2) CHINA-RoHS conform
    Explanation: Compliant with the Restriction of Hazardous Substances (CHINA-RoHS) directive. See further details. China RoHS

    For further assistance: schurter.webleads@schurter.ch
  • 3) 3) non CHINA-RoHS conform [?]
    Term: 3) 3) non CHINA-RoHS conform
    Explanation: Compliant with the Restriction of Hazardous Substances (CHINA-RoHS) directive. See further details: China RoHS

    For further assistance: schurter.webleads@schurter.ch
  • V-Lock [?]
    Term: V-Lock
    Explanation: Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset.

    For further assistance: schurter.webleads@schurter.ch
  • 2.5 A
  • 6 A
  • 10 A
  • 16 A
  • Sandwich
  • Screw
  • Snap-in
  • Snap-in or screw-on
  • One step
  • Universal
  • individual step
  • Mounting Position 1
  • Mounting Position 1& 2
  • Mounting Position 2
  • Front-/Rear-Side
  • Front-Side
  • Frontside
  • Rear-Side
  • from front side
  • 1-pole
  • 2-pole
  • 1 or 2 pole
  • TA35 1-pole
  • TA35 2-pole
  • TA45 2-pole
  • 5 x 20
  • 5 x 20 or 6.3 x 32
  • 1-pole
  • 2-pole
  • 1 or 2 pole
  • optional, 1 or 2 pole
  • Step switch
  • jumper
  • series-parallel
  • step
CMF1, SGE GST, PG05, Kombielement Leiterplatte 2,5A ohne Filter s/w  VDE cURusChinaCE SelbsteklarationCMF1, CMF4
html pdf cad
pcs e-Shop
1), 2)
mating connection
outlets
2.5 A Snap-in or screw-on Rear-Side PCB 1-pole C8
C8_70C_2pol
unwired
CMF2, SGE GST, PG05, Kombielement Leiterplatte 2,5A ohne Filter s/w  VDE cURusChinaCE SelbsteklarationCMF2, CMF5
html pdf cad
e-Shop
1), 2)
mating connection
outlets
2.5 A Snap-in or screw-on Rear-Side PCB 1-pole C8p
C8_70C_polarisiert_3pol
unwired
CMF3, SGE GST, PG05, Kombielement Leiterplatte 2,5A ohne Filter s/w  VDE cURusChinaCE SelbsteklarationCMF3, CMF6
html pdf cad
pcs e-Shop
1), 2)
mating connection
outlets
2.5 A Snap-in or screw-on Rear-Side PCB 1-pole C6
C6_70C_3pol
unwired
2565-K, SGE GST, PG05, KE/Frontplatte/2.5A/ohne Filter  VDE CE SelbsteklarationCCSAUL2565-K
html pdf
e-Shop
1)
mating connection
outlets
2.5 A Snap-in One step Front-Side Solder, Quick Connect or PCB Terminal 1 or 2 pole C6
C6_70C_3pol
KEB1, SGE GST, PG05, Kombielement Frontplatte 10A ohne Filter  KEB1, SGE GST, PG05, Kombielement Frontplatte 10A ohne Filter  VDE URChinaCE SelbsteklarationCSAKEB1
html pdf cad
pcs e-Shop
1), 2)
mating connection
outlets
optional
Assorted Covers, Cord retaining kits
10 A Snap-in or screw-on One step Mounting Position 2 Front-/Rear-Side Quick connect terminals 4.8 x 0.8 mm 1-pole C14
C14_Stecker_3_polig
Version with line filter
KFB1
prewired
KEB2, SGE GST, PG05, Kombielement Frontplatte 10A ohne Filter  KEB2, SGE GST, PG05, Kombielement Frontplatte 10A ohne Filter  VDE URChinaCE SelbsteklarationCSAKEB2
html pdf cad
pcs e-Shop
1), 2)
mating connection
outlets
optional
Assorted Covers, Cord retaining kits
10 A Snap-in or screw-on One step Mounting Position 2 Front-/Rear-Side Quick connect terminals 4.8 x 0.8 mm 2-pole C14
C14_Stecker_3_polig
Version with line filter
KFB2
prewired
DC11, SGE GST, PG05, Kombielement Frontplatte 10A ohne Filter s/w  DC11, SGE GST, PG05, Kombielement Frontplatte 10A ohne Filter s/w  ENEC 10cURusChinaCE SelbsteklarationDC11
html pdf cad
pcs e-Shop
1), 2) V_Lock_Logo
mating connection
outlets
optional
Assorted Covers, Wire Harness, Cord retaining kits
10 A Snap-in or screw-on One step Mounting Position 2 Front-/Rear-Side Quick connect terminals 4.8 x 0.8 mm 1 or 2 pole C14
C14_Stecker_3_polig
Version with line filter
DC12
Household Equipment
prewired
1074, SGE GST, PG05, KE/Frontplatte/10A/ohne Filter  VDE URCCSAUL1074
html pdf cad
e-Shop
1)
mating connection
outlets
optional
Assorted Covers
10 A Snap-in Universal Mounting Position 2 Front-Side Solder terminals or quick connect terminals 1-pole C14
C14_Stecker_3_polig
6010-K, SGE GST, PG05, KE/Frontplatte/10A/ohne Filter  ENEC 10URCE SelbsteklarationCCSAUL6010-K
html pdf cad
e-Shop
1)
mating connection
outlets
10 A Snap-in One step Mounting Position 1 Front-Side Solder, Quick Connect or Screw Terminals 1 or 2 pole C14
C14_Stecker_3_polig
DC21, SGE GST, PG05, Kombielement Leiterplatte 10A ohne Filter  DC21, SGE GST, PG05, Kombielement Leiterplatte 10A ohne Filter  ENEC 10cURusCE SelbsteklarationDC21
html pdf cad
pcs e-Shop
1), 2) V_Lock_Logo
mating connection
outlets
optional
Cord retaining kits
10 A Screw Rear-Side For PCB mounting 2-pole C14
C14_Stecker_3_polig
Version with line filter
DC22
prewired
NEW
DD11, SGE GST, PG05, Kombielement Frontplatte 10A ohne Filter
ENEC 10cURusCE SelbsteklarationDD11
html pdf cad
pcs e-Shop
1), 2) Medical.jpg
mating connection
outlets
optional
Wire Harness, Cord retaining kits
required
Fusedrawer 2
10 A Screw Front-/Rear-Side Quick connect terminals 4.8 x 0.8 mm 2-pole 5 x 20 1 or 2 pole C14
C14_Stecker_3_polig
Version with line filter
DD12
prewired
NEW
DD21
ENEC 10cURusDD21
html pdf
pcs e-Shop
1), 2) Medical.jpg
mating connection
outlets
required
Fusedrawer 2
10 A Screw Rear-Side For PCB mounting 2-pole 5 x 20 1 or 2 pole C14
C14_Stecker_3_polig
Version with line filter
DD22
prewired
KM, SGE GST, PG05, Kombielement Frontplatte 10A ohne Filter s/w  KM, SGE GST, PG05, Kombielement Frontplatte 10A ohne Filter s/w  ENEC 10cURusChinaCE SelbsteklarationKM
html pdf cad
pcs e-Shop
1), 2) Medical.jpg
mating connection
outlets
optional
Assorted Covers, Wire Harness, Cord retaining kits
required
Fusedrawer 2
10 A Snap-in individual step Mounting Position 2 Front-Side Quick connect terminals 4.8 x 0.8 mm 2-pole 5 x 20 1 or 2 pole C14
C14_Stecker_3_polig
Version with line filter
KMF
with or without shield prewired
KD, SGE GST, PG05, Kombielement Frontplatte 10A ohne Filter s/w  KD, SGE GST, PG05, Kombielement Frontplatte 10A ohne Filter s/w  ENEC 10URChinaCE SelbsteklarationCSAKD
html pdf cad
pcs e-Shop
1), 2) V_Lock_Logo Medical.jpg
mating connection
outlets
optional
Assorted Covers, Wire Harness, Cord retaining kits
required
Fusedrawer 3
10 A Snap-in or screw-on One step Mounting Position 1 Front-/Rear-Side Quick connect terminals 4.8 x 0.8 mm 2-pole 5 x 20 or 6.3 x 32 1 or 2 pole step C14
C14_Stecker_3_polig
Version with line filter
CD
prewired
KD, SGE GST, PG05, Kombielement Frontplatte 10A ohne Filter s/w  ENEC 10URChinaCE SelbsteklarationCSAKD-Bowdencable
html pdf
e-Shop
Medical.jpg
mating connection
outlets
optional
Cord retaining kits
required
Bowdencables incl. accessory, Fusedrawer 3
6 A Snap-in or screw-on One step Mounting Position 1 Front-/Rear-Side Quick connect terminals 4.8 x 0.8 mm 2-pole 5 x 20 or 6.3 x 32 1 or 2 pole step C14
C14_Stecker_3_polig
Version with line filter
CD-Bowdencable
with line switch for Bowdencable prewired
KG, SGE GST, PG05, Kombielement Frontplatte 10A ohne Filter  KG_snap  ENEC 10URCE SelbsteklarationCSAKG
html pdf cad
pcs pcn e-Shop
1), 2) V_Lock_Logo Medical.jpg
mating connection
outlets
optional
Assorted Covers, Cord retaining kits
required
Jumper Wire 1, Fusedrawer 1, Voltage Selectors Insert 1
10 A Snap-in or screw-on One step Mounting Position 1 Front-/Rear-Side Quick connect terminals 4.8 x 0.8 mm 2-pole 5 x 20 or 6.3 x 32 1 or 2 pole series-parallel C14
C14_Stecker_3_polig
Version with line filter
CG
partially wired
KG, SGE GST, PG05, Kombielement Frontplatte 10A ohne Filter  ENEC 10URCE SelbsteklarationCSAKG-Bowdencable
html pdf cad
e-Shop
Medical.jpg
mating connection
outlets
optional
Cord retaining kits
required
Bowdencables incl. accessory, Jumper Wire 1, Fusedrawer 1, Voltage Selectors Insert 1
6 A Snap-in or screw-on One step Mounting Position 1 Front-/Rear-Side Quick connect terminals 4.8 x 0.8 mm 2-pole 5 x 20 or 6.3 x 32 1 or 2 pole series-parallel C14
C14_Stecker_3_polig
Version with line filter
CG-Bowdencable
with line switch for Bowdencable partially wired
GRM1, SGE GST, PG05, Kombielement Frontplatte 10A ohne Filter s/w  ENEC 10cURusCE SelbsteklarationGRM1
html pdf
e-Shop
1), 2) V_Lock_Logo
mating connection
outlets
10 A Snap-in One step Mounting Position 1 Rear-Side Quick connect terminals 4.8 x 0.8 mm 2-pole 5 x 20 1 or 2 pole jumper C14
C14_Stecker_3_polig
Version with line filter
GRM2, GRM4
fuse on rear-side prewired
6765_6621a10048_GST_PG07_Gerätest_Vorrichtungen   URCE SelbsteklarationCCSAULENEC 146765
html pdf cad
pcs e-Shop
1)
mating connection
outlets
optional
Wire Harness
10 A Screw Front-/Rear-Side Solder terminals or quick connect terminals 2-pole 5 x 20 1 or 2 pole C14, C18
C14_Stecker_3_polig  2_polig
6762_9998a300024_GST_PG05   6762_SGE_GST_PG05_KE_Kombielement_Frontplatte_10A_ohne Filter  URCE SelbsteklarationCCSAULENEC 146762
html pdf cad
pcs e-Shop
1)
mating connection
outlets
optional
Wire Harness
10 A Snap-in or screw-on Universal Mounting Position 2 Front-Side Solder terminals or quick connect terminals 1 or 2 pole 5 x 20 1-pole C14, C18
C14_Stecker_3_polig  2_polig

Indicated types: 1 - 20 of 50